Edwards RV5 Rotary vane pump
5.8 m3h-1, 3.4 ft3min-1, 96.7 l min-1

Direct drive vane vacuum pump. CFM 4.1, Ultimate vacuum 1.5 x 10-3 torr, Inlet / exhaust ports NW25, Motor 300W 50/60hz 115v /240 volt standard or optional 200-460v 3ph 50/60hz, Oil capacity 0.7 liter, Weight net 47.3 lbs.

Typical use of these pumps would be as follows.
  • Laboratory research
  • Pharmaceutical applications
  • Freeze drying and gel drying
  • Composite moulding and silicone resin degassing
  • Backing of diffusion pumps and turbo molecular pumps
  • Vacuum bagging
  • UHV ultra high vacuum systems
  • Vacuum filtration
  • Centrifuge concentration
  • Distillation and extraction apparatus
  • Glove boxes , fume hoods and vacuum load locks
  • Recirculation of rare gases such as helium
  • Azide applications
  • Vacuum furnaces and vacuum ovens
  • Electron microscopes , mass spectrometers and lasers
  • Air conditioning refrigeration and dehydration

Edwards RV5 Rotary vane pump
Technical Data

Displacement
50 Hz operation 5.8 m3h-1 / 3.4 ft3min-1
60 Hz operation 7.0 m3h-1 / 4.1 ft3min-1
Speed (Pneurop 6602)
50 Hz operation 5.1 m3h-1 / 3 ft3min-1
60 Hz operation 6.2 m3h-1 / 3.6 ft3min-1
GAS BALLAST         ULTIMATE VACUUM (TOTAL PRESSURE)
                                     HIGH VACUUM MODE             HIGH THROUGHPUT MODE
Closed                        2 x 10-3 mbar /                             3 x 10-2 mbar /
                                     1.5 x 10-3 Torr                              2.3 x 10-2 Torr
Low flow, I                 3 x 10-2 mbar /                             6 x 10-2 mbar /
                                     2.3 x 10-2 Torr                              4.6 x 10-2 Torr
High flow, II                                                                      1 x 10-1 mbar /
                                                                                            9.1 x 10-2 Torr
Inlet connection
NW25
Outlet connection
NW25
Maximum allowed outlet pressure
1 bar gauge / 14 psig
Maximum allowed inlet and gas ballast pressure
0.5 bar gauge / 7 psig
Maximum water vapor inlet pressure
50 mbar / 38 Torr
Maximum water vapor pumping rate
Gas ballast low flow
60 g h-1
Gas ballast high flow
220 g h-1
Motor power
50Hz 250 W
60Hz 300 W
Electrical supply
1-phase
110-120 V or 220-240 V,
50 or 60 Hz
3-phase
200-230 V or 380-460 V,
50 or 60 Hz
Operating temperature range
12 – 40 ºC
Weight, without oil
21.5 kg / 43 lbs
Noise
48 dB(A)@ 50 Hz
Oil capacity
Maximum 0.7 liter
Minimum 0.42 liter
Recommended oil
 Ultragrade 19

Edwards RV5 Rotary vane pump

Total Pressure

Edwards RV5 Rotary vane pump

1 50 Hz high vacuum mode, gas ballast = 0
2 50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3 50 Hz high vacuum and high throughput modes, gas ballast = I

Edwards RV5 Rotary vane pump
1 60 Hz high vacuum mode, gas ballast = 0
2 60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3 60 Hz high vacuum and high throughput modes, gas ballast = I

Edwards RV5 Rotary vane pump

Diagram

Edwards RV5 Rotary vane pump


Edwards RV5 Rotary vane pump

Ordering information


Edwards RV5 pump
115/230 V, 1-ph, 50/60 Hz,
Factory set to 230 V for Europe A65301903
Factory set to 115 V for USA A65301906
100/200 V, 1-ph, 50/60 Hz
Factory set to 200 V for Japan A65301904
200-220/380-415 V, 3-ph, 50 Hz and 200-230/460 V, 3-ph, 60 Hz
Factory set to 380/460 V A65301905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and "O" ring.

Edwards RV5 ACCESSORIES
2 m electrical supply cable with IEC socket for 1-ph pumps
UK, three-pin plug A50505000
North European plug A50506000
North America/Japan plug A50507000
No plug A50508000
RV gas-ballast adaptor A50502000
RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose A50509000
EMF10 outlet mist filter A46226000

Edwards RV5 SPARES
The clean and overhaul kit contains all of the springs, gaskets, seals and other
components required for routine maintenance and whenever the pump is dismantled.
Add a blade kit for a full service.
Clean and overhaul kit A65201131
Blade kit A65301130
Outer shaft seal kit A65201134
Inlet valve kit A65201036
Cartridge kit A65301032

PRODUCT DESCRIPTION | ATEX CLASSIFICATION  | ORDER NUMBER
RV5 pump – flameproof motor options
ATEX RV5 230 V, 1-ph, 50 Hz II 2G IIB T4 External A65318991
ATEX RV5 230 V, 1-ph, 50 Hz II 2G IIC T4 External A65318989
ATEX RV5 230 V, 1-ph, 60 Hz II 2G IIB T4 External A65318988
ATEX RV5 230 V, 1-ph, 60 Hz II 2G IIC T4 External A65318990
ATEX RV5 115 V, 1-ph, 60 Hz II 2G IIB T4 External A65318987
ATEX RV5 115 V, 1-ph, 60 Hz II 2G IIC T4 External A65318986
ATEX RV5 400 V, 3-ph, 50 Hz II 2G IIB T4 External A65318993
ATEX RV5 400 V, 3-ph, 50 Hz II 2G IIC T4 External A65318992
ATEX pumps with flameproof motors require the user to provide:
2 off hazardous area cable glands and cables.
Connection of the thermistors to an appropriate safety circuit to switch off the pump if overheating
occurs.

RV5 pump – PFPE prepared*
115/230 V, 1-ph, 50/60 Hz,
Factory set to 230 V for Europe A65309903
Factory set to 115 V for USA A65309906
100/200 V, 1-ph, 50/60 Hz
Factory set to 200 V for Japan A65309904
200-220/380-415 V, 3-ph, 50 Hz and 200-230/460 V, 3-ph, 60 Hz
Factory set to 380/460 V A65309905
* PFPE fluid not included.



we also hire vacuum  pumps, we buy vacuum pumps
we also do service exchange, recon, reconditioned and remanufactured pumps

Absolute vacuum services sells, supplies, stocks and distributes vacuum products, pumps and spares

Absolute vacuum services uk  United Kingdom
UK Tel: +44 (0) 1273 891 450
Fax: +44 (0) 1273 891 451