Edwards® Vacuum (formerly BOC Edwards®)
Absolute vacuum sell and service Edwards® rv3 vacuum pumps

Edwards® RV3 Rotary vane pump
3.7 m3h-1, 2.2 ft3min-1, 61.7 l min-1
Direct drive vane vacuum pump. CFM 2.6, Ultimate vacuum 1.5 x
10-3 torr, Inlet / exhaust ports NW25,
Motor 300W 50/60hz 115v 240 volt standard or
optional 200-460v 3ph 50/60hz, Oil capacity 0.7 liter, Weight net 47.3 lbs
Typical use of RV3 rotary vane pumps:
- Laboratory research
- Pharmaceutical applications
- Freeze drying and gel drying
- Composite moulding and silicone resin degassing
- Backing of diffusion pumps and turbo molecular pumps
- Vacuum bagging
- UHV ultra high vacuum systems
- Vacuum filtration
- Centrifuge concentration
- Distillation and extraction apparatus
- Glove boxes , fume hoods and vacuum load locks
- Recirculation of rare gases such as helium
- Azide applications
- Vacuum furnaces and vacuum ovens
- Electron microscopes , mass spectrometers and lasers
- Air conditioning refrigeration and dehydration.
RV3 Rotary Vane pump - technical data
Displacement50 Hz operation 3.7 m3h-1 / 2.2 ft3min-160 Hz operation 4.5 m3h-1 / 2.6 ft3min-1Speed (Pneurop 6602)50 Hz operation 3.3 m3h-1 / 2 ft3min-160 Hz operation 3.9 m3h-1 / 2.3 ft3min-1GAS BALLAST ULTIMATE VACUUM (TOTAL PRESSURE) HIGH VACUUM MODE HIGH THROUGHPUT MODEClosed 2 x 10-3 mbar / 3 x 10-2 mbar / 1.5 x 10-3 Torr 2.3 x 10-2 TorrLow flow, I 3 x 10-2 mbar / 6 x 10-2 mbar / 2.3 x 10-2 Torr 4.6 x 10-2 TorrHigh flow, II 1.2 x 10-1mbar / 9.1 x 10-2 TorrInlet connection
NW25Outlet connection
NW25Maximum allowed outlet pressure
1 bar gauge / 14 psigMaximum allowed inlet and gas ballast pressure0.5 bar gauge / 7 psigMaximum water vapor inlet pressure
80 mbar / 60 TorrMaximum water vapor pumping rateGas ballast low flow 60 g h-1Gas ballast high flow 220 g h-1Motor power50Hz 250 W60Hz 300 WElectrical supply1-phase 110-120 V or220-240 V, 50 or 60 Hz3-phase 200-230 V or380-460 V, 50 or 60 HzOperating temperature range
12 – 40 ºCWeight,
without oil 21.6 kg / 47.3 lbsNoise
48 dB(A) @ 50 HzOil capacityMaximum
0.7 literMinimum
0.42 literRecommended oil
Ultragrade 19
RV3 Rotary Vane pump - total pressure

1 50 Hz high vacuum mode, gas ballast = 0
2 50 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3 50 Hz high vacuum and high throughput modes, gas ballast = II

1 60 Hz high vacuum mode, gas ballast = 0
2 60 Hz high throughput mode, gas ballast = 0 and high vacuum mode, gas ballast = I
3 60 Hz high vacuum and high throughput modes, gas ballast = II
RV3 Rotary Vane pump - diagram

1 1-phase motor
2 3-phase motor
3 Retractable handle
RV3 Rotary Vane pump - Ordering information
RV3 pump
115/230 V, 1-ph, 50/60 Hz
Factory set to 230 V for Europe A65201903
Factory set to 115 V for USA A65201906
100/200 V, 1-ph, 50/60 Hz
Factory set to 200 V for Japan A65201904
200-220/380-415 V, 3-ph, 50 Hz and 200-230/460 V, 3-ph, 60 Hz
Factory set to 380/460 V A65201905
Supplied with: 1 liter of Ultragrade 19 oil, inlet filter and "O" ring.
ACCESSORIES
2 m electrical supply cable with IEC socket for 1-ph pumps
UK, three-pin plug A50505000
North European plug A50506000
North America/Japan plug A50507000
No plug A50508000
RV gas-ballast adaptor A50502000
RV exhaust nozzle kit, £/4 inch BSP to 15 mm hose A50509000
EMF10 outlet mist filter A46226000
SPARES
The clean and overhaul kit contains all of the springs, gaskets, seals and other
components required for routine maintenance and whenever the pump is dismantled.
Add a blade kit for a full service.
Clean and overhaul kit (Viton®) A65201131
Blade kit A65201130
Outer shaft seal kit A65201134
Inlet valve kit A65201036
Cartridge kit A65201032
PRODUCT DESCRIPTION | ATEX CLASSIFICATION | ORDERING NUMBER
RV3 pump – flameproof motor options
ATEX RV3 230 V, 1-ph, 50 Hz II 2G IIB T4 External A65218991
ATEX RV3 230 V, 1-ph, 50 Hz II 2G IIC T4 External A65218989
ATEX RV3 230 V, 1-ph, 60 Hz II 2G IIB T4 External A65218988
ATEX RV3 230 V, 1-ph, 60 Hz II 2G IIC T4 External A65218990
ATEX RV3 115 V, 1-ph, 60 Hz II 2G IIB T4 External A65218987
ATEX RV3 115 V, 1-ph, 60 Hz II 2G IIC T4 External A65218986
ATEX RV3 400 V, 3-ph, 50 Hz II 2G IIB T4 External A65218993
ATEX RV3 400 V, 3-ph, 50 Hz II 2G IIC T4 External A65218992
ATEX pumps with flameproof motors require the user to provide:
2 off hazardous area cable glands and cables.
Connection of the thermistors to an appropriate safety circuit to switch off the pump if overheating
occurs.
RV3 pump – PFPE prepared*
115/230 V, 1-ph, 50/60 Hz
Factory set to 230 V for Europe A65209903
Factory set to 115 V for USA A65209906
100/200 V, 1-ph, 50/60 Hz
Factory set to 200 V for Japan A65209904
200-220/380-415 V, 3-ph, 50 Hz and 200-230/460 V, 3-ph, 60 Hz
Factory set to 380/460 V
we also hire vacuum pumps, we buy vacuum pumps
we also do service exchange, recon, reconditioned and remanufactured pumps
email
Absolute vacuum services sells, supplies, stocks and distributes vacuum products, pumps and spares
Absolute vacuum services uk united kingdom
UK
Tel: +44 (0) 1273 891 450
Fax: +44 (0) 1273 891 451
email absolute vacuum