Vacuum valves: Edwards (formely known as BOC Edwards) vacuum valves

Edwards IPVA10EK Solenoid Operation Air Admittance Valve

Edwards vacuum valves - overview
Edwards SP Speedivalve manual operation isolation valves - NW flanges | Edwards SP manual operation isolation valves - NPT and BSP
Edwards IBV series vacuum ball valves | Edwards PVMK manual operation isolation valves | Edwards PVPK pneumatic operation isolation valves
Edwards PVEK solenoid isolation valves | Edwards LCPVEK solenoid isolation valves | Edwards SIP VP soft start isolation valves
Edwards BRV backing/roughing valves | Edwards GV manual & pneumatic gate valves | Edwards GVA/AVA Aluminium gate/angle valves
Edwards industrial quarter swing butterfly valve | Edwards QSB quarter swing butterfly valves | Edwards electroneumatic valves
Edwards AV5A air admit valve | Edwards AV10K air admit valve | Edwards IPVA10EK solenoid air admit valve
Edwards LV10K fine control needle valve | Edwards FCV10K fine control needle valve


Edwards IPVA10EK Solenoid Operation Air Admittance Valve


The IPVA10EK is a solenoid operated valve designed for automatic admittance of air or vent gas into a vacuum system. The valve has two ports with NW flanges. One of the valve ports is connected to the vacuum system, the other port can be left open to atmosphere or connected to a vent gas supply. The vacuum system is isolated from atmosphere (or the vent gas suppply) by a fluoroelastomer pad on the base of the valve plunger, which seals against the body of the valve.

Normally open and normally closed versions of the valve suitable for use with different electrical supplies are available to suit your application


Technical data - Edwards IPVA10EK Solenoid Operation Air Admittance Valve

Operating temperature range: -20 – 55°C

Vent gas temperature range: -10 – 130°C

Venting rate: 10 litres in 12s

Response time: 30ms

Maximum cycle frequency: 100min-1

Reliablity (MTTF): 105 cycles

Leak rate: 1 x10-9 mbar | s -1/ 8x10-10 Torr | s -1

Electrical supply: 12 V, 24 V, 100 V, 240 V a.c.

Tolerance: d.c -5% to +10% a.c. -10% to +10%

Power: a.c. supply: p.3 VA inrush 6.3 VA hold | d.c. Supply: 5W

Enclosure rating: IP65

Weight: 310g / 11 oz

Construction materials:

Body: Aluminium

Actuator: Fluoroelastomer

Coil insulation: Class F

The air or vent gas path through the valve is free from heavy metals


Edwards IPVA10EK Solenoid Operation Air Admittance Valve


Ordering information - Edwards IPVA10EK Solenoid Operation Air Admittance Valve

IPVA10EK valve, normally open

240 V a.c. C41721000

110 V a.c. C41722000

24 V d.c. C41723000

24 V a.c. C41724000

12 V d.c. C41725000

IPVA10EK valve, normally open

240 V a.c. C41731000

110 V a.c. C41732000

24 V d.c. C41733000

24 V a.c. C41734000

12 V d.c. C41735000