Precision Vacuum parts plus spares. Edwards plus other manufacturers
Edwards® full parts and spares list
........................................................
Edwards 3000 vacuum pump ........................................................
Edwards 1900 vacuum pump ........................................................
Edwards GV400 vacuum pump ........................................................
Edwards Blowers (Rootes pumps) ........................................................
Full parts and spares list ........................................................
Edwards Blowers (Rootes pumps): ........................................................
Edwards e2m2 vacuum pump ........................................................
Edwards e1m5 vacuum pump ........................................................
Edwards e2m5 vacuum pump ........................................................
Edwards e1m8 vacuum pump ........................................................
Edwards e2m8 vacuum pump ........................................................
Edwards e2m12 vacuum pump ........................................................
Edwards e1m18 vacuum pump ........................................................
Edwards e2m18 vacuum pump ........................................................
Edwards e2m28 vacuum pump ........................................................
Edwards e2m30 vacuum pump ........................................................
Edwards e1m40 vacuum pump ........................................................
Edwards e2m40 vacuum pump ........................................................
Edwards e1m80 vacuum pump ........................................................
Edwards e2m80 vacuum pump ........................................................
Edwards e1m175 vacuum pump ........................................................
Edwards e2m175 vacuum pump ........................................................
Edwards e1m275 vacuum pump ........................................................
Edwards e2m275 vacuum pump ........................................................
EH250 blower ........................................................
EH500A blower ........................................................
EH1200 blower ........................................................
EH2600 blower ........................................................
EH4200 blower ........................................................
Edwards Turbo pumps ........................................................
Edwards Speedivalves ........................................................
Edwards Vacuum pumps: ........................................................
RV3 Vacuum pump ........................................................
RV5 Vacuum pump ........................................................
RV8 Vacuum pump ........................................................
RV12 Vacuum pump ........................................................
Edwards Hook and claw pumps ........................................................
Edwards scroll pumps ........................................................
Edwards GV Series ........................................................
Edwards GVM Series ........................................................
Edwards EM Series Oil pumps ........................................................
Edwards drystar pumps ........................................................
Edwards vacuum oils: ........................................................
edwards 8A oil ........................................................
edwards supergrade A ........................................................
edwards 17 oil ........................................................
edwards 20 oil ........................................................
edwards 16 oil ........................................................
edwards 18 oil ........................................................
edwards ultragrade 15 ........................................................
edwards ultragrade 19 ........................................................
edwards ultragrade 20 ........................................................
edwards ultragrade 70 ........................................................
edwards 45 grade oil
Absolute Vacuum News
About Absolute Vacuum
Absolute Vacuum Location
Contact Absolute Vacuum
Absolute Vacuum Payment Methods
Absolute Vacuum Terms & Conditions
Absolute Vacuum Warranty Guarantee
Absolute Vacuum Testimonials
Absolute Vacuum Sponsorship
Absolute Vacuum Export
|
|
|
|
Absolute Vacuum present: Edwards® Calibration equipment
Edwards® EC6ST 6 Port Calibration System

Edwards® EC6ST 6 Port Calibration System
Features
& benefits
- Quality standards including ISO 9000
- Calibration
from 1000 mbar to 10'6 mbar
- Simultaneous
calibration of multiple gauges
- Baking facility to reduce cycle times
Edwards® EC6ST 6 Port Calibration System
- Designed to enable gauge users
to comply with quality standards
- Suitable for commercial military and government
establishments.
- Regular calibration of
measuring equipment used in production processes.
The majority of vacuum applications operate within the pressure range 1000 mbar
to 10-6 mbar, with instruments most often requiring
calibration being:
- Capsule gauges,
- Thermal conductivity types
- Pirani gauges
- Thermocouple gauges
- Magnetron gauges
- Hot cathode
ionisation gauges.
- Calibration system: six-port chamber fitted with a
liquid nitrogen cold trap
- Chamber capable of isolation from the
turbomolecular pump via manually operated isolation valve
- Chamber is 'roughed' by a rotary pump connected via an electrically activated valve.
- Used as a 'backing' pump for the turbo as secondary purpose
- Calibration
gas admitted to system via a narrow pipe
- Dis-charging
gas towards domed top of the chamber.
- Flow of gas controlled
by a manually operated fine control needle valve
- Calibration performed by connecting test gauges to the chamber
- Evacuating to a base pressure at least a decade and a half below
the lowest point to be calibrated.
- Calibration gas inlet valve increases the pressure
- Readings on the test
gauge compared to that of the reference master gauge.
Edwards® EC6ST 6 Port Calibration System
Technical
Data
Base
pressure (cold trap empty) 5 x 10
-8 mbar after 5-10 hours (typically) Chamber
volume 5 liters Test
ports Total 6. 4 ports used
by reference gauges Gas
inlet control Fine control
needle valve System
pressure control Manual gas
inlet and pumping speed control Reference
gauges 1 x 10 -6 to 5 x 10-3 mbar (ion gauge)
1
x 10-3 to 1 mbar (1 mbar range Barocel) 0 to 10 mbar (1 (1
mbar range Barocel) 1 to 1 000 mbar (1 000 mbar range
Barocel) Note- Other gauges available on request.
Vacuum
pumps Turbo pump EXT250, DN1OOCF Rotary pump RV5 Baking
temperature 90 ° C
Dimensions see
diagram Vacuum Weight packed:
400 kg Unpacked: 200 kg

Edwards® EC6ST 6 Port Calibration System
Part Information
EC6ST – 6 port
calibration system (230 V 50 Hz): D15487000
EC6ST – 6 port
calibration system (115 V 60 Hz): D15488000
|
|
|