Absolute Vacuum present the Edwards® TIC turbo & instrument
controller

- Compact turbo and instrument
controller
- Large clear graphical display
- Intuitive user interface
- Serial
communications
- Full remote control
- Data logging functions
- PC control software
- Automatic recognition
and support of up to three gauges from the Edwards range (excluding IGC
and Barocels), and one 24 V turbomolecular pump from the EXT range.
- Cooling and vent valve support via
controller.
- Backing pump control
- The TIC turbo and instrument controller either rack or bench mounted
To
initiate turbo pumps and low pressure gauges, high pressure gauges can be employed, or, time
delays and normal signals may be used to control turbo
and instrument initiation. A comprehensive array of protection
and safety interlock features are provided.
Edwards® TIC turbo & instrument
controller - Technical data
|
Edwards® Turbo pump 24 V
|
|
Turbo pump options
Edwards® EXT75DX
Edwards® EXT255H & EXDC80*
Edwards® EXT255H & EXDC160
Edwards® EXT255DX
* Ramp speed is limited by the use
of the EXDC80
** When configured to low power start
|
100 W
Fast
Slow
N/A
Slow**
|
200 W
Fast
Slow
Fast Fast
|
|
Logic Interface
Control inputs
Turbo start/stop*
Turbo standby
Gauge enable 1, 2, 3
Backing pump start/stop*
System interlock SYSI
Control outputs
Vent valve control
Heater band control
Backing pump control
Air cooler
Status outputs
Analog output
Set point A, B, C
Turbo normal speed
Alarm
Serial interface
* Start/stop commands are "edge triggered".
|
The logic interface connector
includes the functions listed below. It may be used either to link
to system relays, a higher-level control system, or an optional
relay box. By utilizing the relay box pass through connector, a
combination of a higher-level control system and relay box may be
used.
Closed when low: < 0.5 V d.c.
Open when High: 4 to 24 V d.c.
Closed when low: < 0.5 V d.c.
Open when High: 4 to 24 V d.c.
Closed when low: < 0.5 V d.c.
Open when High: 4 to 24 V d.c.
Closed when low: < 0.5 V d.c.
Open when High: 4 to 24 V d.c.
Closed when low: < 0.5 V d.c.
Open when High: 4 to 24 V d.c.
O/C 24 V d.c. 100 mA
O/C 24 V d.c. 50 mA
O/C 24 V d.c. 100 mA
O/C 24 V d.c. 200 mA
0-10 V d.c.
O/C 24 V d.c. 50 mA
O/C 24 V d.c. 50 mA
O/C 24 V d.c. 50m A
The TIC has two built-in communications protocols, RS232 and
RS485. These may be used either to interface to a PLC or, using
the WindowsTM PC software package supplied connected to a PC for
full monitoring and control of a TIC system.
|
|
Power consumption (max)
|
TIC turbo & instrument
controller 100 W RS232
215 VA
|
TIC turbo & instrument
controller 200 W RS232
350 VA
|
|
Electrical supply
Peak inrush current
Fuse
Earth stud
Auxiliary terminals
Air cooling fan
Vent valve
Interface cables
Dimensions
Electronics housing
Front panel
Weight
Turbo & instrument controller
100 W RS232
Turbo & instrument controller
200 W RS232
Operating temperature
Storage temperature
Maximum ambient operating humidity
Maximum operating altitude
Electronic Design
Electromagnetic Compatibility
Industrial Location, Class B Emissions
Enclosure rating
|
90 to 264 V a.c. 47 to 63 Hz
10.3 A @ 110 V a.c.
23.0 A @ 230 V a.c.
TIC is self-protecting and has no
user replaceable fuse. The unit will recover when the overload is
removed
M4
24 V d.c. 3 W max, ACX70, ACX75 &
ACX250H
24 V d.c. 2 W max, TAV5 & TAV6
Use cables as specified in "ordering
information"
110 mm high x 105 mm wide x 245 mm
deep
106 mm wide x 128 mm high
2.75 KG
3.5 KG
+0 ° to +40 °C
-30 °
to +70 °C
90% RH non-condensing at 40 °C
3000 m
EN 61010-1
EN 61326
IP20
|
Edwards® TIC turbo and instrument controller Bench and rack mounting options (1/4
19" 3U sub rack)

Edwards® TIC turbo and instrument controller External interfaces

Edwards® TIC turbo and instrument controller - Display interface

TIC software - accessed via a
series of user friendly screens.
TIC detects it's environment and setup and displays the appropriate information for connected equipment
Edwards® TIC turbo and instrument controller - Gauge inputs
Instruments supporting TIC variants
recognise and control the following gauges: APG, APGX, ATC, ASG, AIM, WRG &
AIGX*
Edwards® TIC turbo and instrument controller - Backing pump 24 V
200 W turbo supporting TIC variants
recognise and control the XDD1 24 V backing pump
Edwards® TIC turbo and instrument controller - Relay box (optional)
A range of relay boxes are available to allow the Turbo and Instrument controller to operate three 250 V a.c. 3 A
(non-inductive) changeover relays, mains backing pumps and
accessories. Changeover relays are activated by Turbo and Instrument controller set point
outputs. The mains backing pump relay controls a backing line
isolation valve, so that when the backing pump is switched off the
isolation valve closes.
Edwards® TIC turbo and instrument controller - Relay box options

Edwards® TIC turbo and instrument controller - Compatible mains backing pumps and
accessories
Small backing pumps: E2M0.7 & 1.5,
RV3, 5, 8 & 12, XDS5C & 10C, XDS5 & 10 & ESDP12
Heater band: BX70 & BX250
Backing line isolation valve: LCPV16EKA
& LCPV25EKA

Edwards® TIC turbo controller - WindowsTM PC programThe
Edwards TIC turbo controller range is supplied with WindowsTM
based PC software (win32 application), adding to the TIC embedded
control menus. This enables Edwards TIC systems to be configured,
controlled and monitored from a single PC. Data logging is also
included, which writes configurable parameters to file in .csv format.
These can be analysed. TIC system configurations may be created and
saved later use. The software carries upgrade capabilties. Edwards® TIC turbo and instrument controller - Configuration examples
Item Description Part No.
A TIC turbo/inst cont 200 W RS232*
D39722000
B 2 m UK mains cable D40013025
C WRG-S-NW25 D14701000
D XDD1 24 V d.c. diaphragm pump
A74601991
E EXT75DX ISO63 B72241000
F ACX75 air-cooler B58053075
G XDD/DX/EXDC extension cable 2 m
D39700836
H XDD/DX/EXDC extension cable 2 m (optional) D39700836
J 0.5 m active gauge cable
D40001005
* When using an XDD1 pump, the turbo
should be either controlled by a gauge or be subjected to a start
delay.

Item Description Part No.
A TIC turbo/inst cont 100 W RS232
D39721000
B 2 m UK mains cable D40013025
C TIC relay box small backing
D39711805
D APGX-M-NW25 STST D02372000
E AIGX-S-NW25 D04850000
F WRG-S-NW25 D14701000
G RV3 pump 1-phase A65201903
H EXT75DX ISO63 B72241000
J BX70 heater band 240 V 60 W*
B58052060
K TAV5 vent valve B58066010
L ACX75 air-cooler B58053075
M TIC logic interface cable 2 m
D39700833
N TIC mains cable IEC320 M/F 2 m
D39700831
P TIC logic interface cable 2 m
D39700833
Q XDD/DX/EXDC extension cable 2 m
(optional) D39700836
R TIC RS232 interface cable 2 m
(optional D39700834
S 2 m active gauge cable D40001020
T PC with RS232 interface (optional)
N/A

Item Description Part No.
A TIC turbo/inst cont 200 W RS232
D39722000
B 2 m UK mains cable D40013025
C TIC relay box sml backing
D39711805
D APGX-M-NW16 AL D02371000
E AIGX-S-NW25 D04850000
F WRG-S-NW25 D14701000
G XDS10 A72701903
H EXT255H DN100ISO-K 24 V
D75301991
J EXDC160 24 V D39646000
K TAV5 vent valve B58066010
L ACX250H air-cooler B58053160
M TIC mains cable IEC320 M/F 2 m
D39700831
N TIC logic interface cable 2 m
D39700833
P XDD/DX/EXDC extension cable 2 m
(optional) D39700836
Q RS232 interface cable 2 m (optional)
D39700834
R 1 m active gauge cable
D40001010
S PC with RS232 interface (optional)
N/A
 Product description Part No.
Controllers (supplied with manuals and
software)
TIC turbo & instrument controller
100 W RS232 D39721000
TIC turbo & instrument controller
200 W RS232 D39722000
Relay boxes (supplied with a set of
mating connectors)
TIC relay box instruments (3 x 250 V
a.c. 3 A
changeover relays) D39700804
TIC relay box small backing pump
D39711805
TIC relay box instruments & small
backing pump D39721806
Cables
Mains cables (TIC and relay box supply)
2 m UK plug D40013025
2 m USA plug D40013120
2 m Northern European plug D40013030
Mains cables (relay box to RV and XDS
type pumps)
2 m TIC mains cable IEC320 m/f
D39700831
5 m TIC mains cable IEC320 m/f
D39700832
Interface cables
2 m TIC logic interface cable D39700833
2 m TIC RS232 interface cable D39700834
24 V pump extension cables (use with
EXDC, DX & XDD1 type pumps)
1 m XDD/DX/EXDC extension cable
D39700835
2 m XDD/DX/EXDC extension cable
D39700836
5 m XDD/DX/EXDC extension cable
D39700837
Active gauge cables (include FCC68
compatible connections at both ends)
0.5 m active gauge cable D40001005
1 m active gauge cable D40001010
3 m active gauge cable D40001030
5 m active gauge cable D40001050
10 m active gauge cable D40001100
15 m active gauge cable D40001150
15 m active gauge cable (24 AWG)
D40005150
25 m active gauge cable D40001250
30 m active gauge cable (24 AWG)
D40005300
50 m active gauge cable D40001500
100 m active gauge cable D40001999
Other accessories and supporting
products
TIC front bezel kit (spare) D39700803
|